Hall 1

Hall 1 is circular in shape, covered by a dome spanning 109 m. This is at the moment the largest dome in the world made of prestressed concrete.

Maximum ceiling height at the crown is 30.78 m. The hall was constructed in several levels, including the basement, the arena, the ground floor, 1st gallery, 2nd gallery, and the connecting segment to the West Wing. All levels are used for exhibiting with the exception of basement, where offices, the warehouse, and auxiliary facilities are located.

All external exhibiting area walls are made of glass, from the floor level to the dome.

Total gross floor area is 21,280 m2, of which 15,030 m2 is reserved for the exhibiting space.

This hall has cooling, heating, and ventilation.

Arena

Specifications:

  • Exhibiting area: 3,648 m2
  • Freight entrance maximum dimensions: 465 x 398 cm
  • Cement-coated concrete floor, maximum loading: 1,500 kg/m2
  • Center maximum height: 30.78 m
  • Demonstration high voltage power outlets 3 x 380 V, 50 Hz
  • Lighting: High voltage power outlets 220 V, 50 Hz
  • Telephone connections available at any place
  • Demonstration water inlet and outlet at certain places
  • General illumination inadequate for stand lighting
  • Power connection at any place

Ground Floor

Specifications:

  • Exhibiting area: 5,640 m2
  • Freight entrance to Hall 1A – maximum dimensions: 495 x 310 cm
  • Freight entrance to the Boulevard – maximum dimensions: 450 x 395 cm
  • Doors to the Sava (Vitvang) – maximum dimensions: 580 x 355 m
  • Terrazzo concrete floor, maximum loading: 1,200 kg/m2
  • Maximum height next to the walls under the gallery: 3.95 m
  • Passage width between the escalator and the Arena: 2.2 m
  • Passage width between the stairs and the Arena: 2.25 m
  • Passage width between the stairs to Hall 4 and the Arena: 3 m
  • Demonstration high voltage power outlets 3 x 380 V, 50 Hz
  • Lighting: High voltage power outlets 220 V, 50 Hz
  • Telephone connections available at any place
  • Demonstration water inlet and outlet at certain places
  • General illumination inadequate for stand lighting, other than next to the walls under the gallery
  • Power connection at any place

1st Gallery

Specifications:

  • Exhibiting area: 2,430 m2
  • Freight elevator dimensions: 210 x 150 x 250 cm, capacity: 1,500 kg
  • Terrazzo floor, maximum loading: 800 kg/m2
  • Maximum height up to the 2nd Gallery: 3.4 m
  • Width between columns on the floor: 3.35 m
  • Demonstration high voltage power outlets 3 x 380 V, 50 Hz
  • Lighting: High voltage outlets 220 V, 50 Hz
  • Telephone connections at any place
  • Demonstration water inlet and outlet at certain places
  • General illumination adequate for stand lighting
  • Power connection at any place

2nd Gallery

Specifications:

  • Exhibiting area: 2.430 m2
  • Freight elevator dimensions: 210 x 150 x 250 cm, capacity: 1.500 kg
  • Terrazzo floor, maximum loading: 800 kg/m2
  • Maximum height up to the 2nd Gallery: 3.45 m
  • Demonstration high voltage power outlets 3 x 380 V, 50 Hz
  • Lighting: High voltage outlets 220 V, 50Hz
  • Telephone connections at any place
  • Demonstration water inlet and outlet at certain places
  • General illumination adequate for stand lighting
  • Power connection at any place

3rd Gallery

Specifications:

  • Exhibiting area: 3,422 m2
  • Freight elevator dimensions: 200 x 180 x 195 cm, capacity: 1,500 kg
  • Terrazzo floor, maximum loading: 600 kg/m2
  • Maximum height next to the hall walls: 5.30 m
  • Demonstration high voltage power outlets 3 x 380 V, 50 Hz
  • Lighting: High voltage power outlets 220 V, 50 Hz
  • Telephone connections at any place
  • Demonstration water inlet and outlet at certain places
  • Power connection at any place